30kV Hipot VLF Hipot Tester

30kV Hipot VLF Hipot Tester

Brand Name:HMDQ; Model:HMCOP-30kV; Controller: 4kg; Booster:20kg; Output wave:sine wave; Measurement accuracy:±3%; Display:LCD Display
Send Inquiry
Description
Technical Parameters

Wuhan Goldhome Hipot Electrical Co., Ltd. is one of the leading manufacturers and suppliers of 30kv hipot vlf hipot tester in China. With abundant experience, our factory offer high quality customized products made in China with competitive price. Welcome to contact us for quotation.

 

Product Overview & Applications

 

1

The 30kV Ultra-Low Frequency Insulation Withstand Voltage Tester features fully automatic voltage ramp-up, ramp-down, measurement, and protection functions. Its fully electronic design ensures a compact size and lightweight construction. A large LCD screen provides clear and intuitive display of output waveforms, while the built-in printer outputs test reports.

 

Industrial Applications:

1. Power Cable Manufacturing Quality Control: Factory testing of newly produced medium-voltage cables (up to 35kV rating).

2. Utility Cable Installation and Commissioning: Field testing of newly laid underground power cables.

3. Preventive Maintenance for Aging Cable Networks: Assessing the condition of in-service medium-voltage cables (5-35kV) in utility grids.

4. Industrial Site Electrical System Maintenance: Inspection of critical power cables in factories, mines, and refineries.

5. Railway and Rail Transit Electrification: Testing of traction cables and feeder cables in railway systems.

6. Renewable Energy Sites: Commissioning and maintenance of underground bus cables in wind farms and photovoltaic power stations.

7. Oil and Gas Industry: Inspection of subsea cables, offshore platform cables, and refinery power distribution systems.

8. Data Center Power Infrastructure: Assurance testing of medium-voltage cables supplying critical data center loads.

9. Mining Industry: Testing of haulage cables, feeder cables, and distribution cables in mines.

10. Cable Repair and Joint Verification: Testing following cable jointing or repair operations.

2

 

Product Features

 

3

 

1. Easiest to use Fully automatic microcontroller
2. Built-in printer
3. True sine wave output
4. Real-time display of actual output waveform
5. Ergonomic, menu guided, large backlit LCD
6. Storage of test results for later retrieval and print.
7. Over voltage and current protected
8. Variable frequency 0.1Hz, 0.05Hz, 0.02 Hz
9. Data of current, voltage and waveform directly sampled at HV side.
10. AC testing does not degrade good cable insulation
11. Harmful space charges are not injected into the cable insulation
12. No traveling waves are generated during testing
13. Rugged and reliable design less prone to failure from transients

 

 

product Parameter

Rated voltage

Load capacity

Fuse

Weight

    30kV

(Peak)

0.1Hz,≤0.5uF
0.05Hz,≤1.1uF
0.02Hz,≤2.2uF
0.01Hz,≤5.5uF

10A

Controller: 4kg

Booster:20kg

4

 

On-Site Test

 

The on-site test diagram for the HMCOP-30kV is as follows:

HMCOp-30kv01

HMCOp-30kv02

 

HMCOp-30kv03

 

Maintenance & FAQs

 

Q: Why is VLF (0.1 Hz) used instead of 50/60 Hz?

A: Applying power-frequency (50/60 Hz) high voltage requires a large, heavy, and expensive test set. VLF testing stresses the insulation in a nearly equivalent manner but with a power supply that is smaller, lighter, and portable, making it practical for field use.

Q:What types of equipment can be tested?

A: Primarily used for:

Medium-voltage power cables(up to 35kV class)

Generators and motors(with specific adapters)

Switchgear and transformers(insulation testing)

Q: Is the 50kV output DC or AC? What is its RMS value?

A: The output is an ultra-low-frequency sinusoidal AC high voltage. 50kV refers to its peak voltage. Converted to equivalent line-frequency AC RMS using the formula: 50kV / √2 ≈ 35kV.

Q:What is the difference between a "Withstand Test" and a "Tan Delta Diagnostic Test"?

A: Withstand (Hipot) Test:Applies a high voltage for a set time to "pass/fail" the insulation. The goal is to see if the insulation breaks down.

Tan Delta (Diagnostic) Test:Measures the dielectric losses (power factor) in the insulation at different voltage levels. This identifies the condition and agingof the insulation without necessarily causing failure.

 

Q: What are the typical test voltages and durations?
A: ​According to standards like IEEE 400.2:

Test Voltage:Typically 2 to 3 times the cable's phase-to-ground voltage (U₀).

Duration:Usually 15 to 60 minutes.

Example:For a 15kV cable (U₀ = 8.7kV), a common test is 2U₀ (17.4kV) for 30-60 minutes

 

Q:What safety precautions are mandatory?

A:The test object must be completely de-energized, isolated, and groundedbefore connecting the tester.

Establish a clearly marked safety boundaryaround the test area.

Use proper PPE:insulated gloves, safety goggles, and flame-resistant clothing.

Always ground the test objectafter the test and before handling.

 

Q: What does a "failed" test indicate?

A:If the insulation breaks down during a withstand test, it indicates a severe weakness, such as:

Water treeing or electrical treeing

Installation damage (cuts, gouges)

Aging and degradation of the insulation material

Hot Tags: 30kV Hipot VLF Hipot Tester, China 30kV Hipot VLF Hipot Tester manufacturers, factory, voltage rectification system, insulation resistance tester, insulation testing service, leakage prevention equipment, voltage rectification protocol, electrical safety standard tester