Product Overview & Application Scenarios
Product Overview
The Transformer Capacity Tester is a specialized field testing device that enables rapid and accurate measurement of a transformer's rated capacity without applying high currents to the transformer. This product use wide-screen color LCD , English display, simple and quick menu operation, human-machine interface is very friendly. There is a built -in rechargeable battery inside the instrument and it can work without external power source. A fully charged battery can be continuously measured more than 100 sets of transformer. This is a multi-functional measuring instrument, which is equivalent to two common meters: such as active transformer capacity tester plus transformer parameter tester. It can be used for test transformer capacity, type, no-load current, no-load loss, load loss, impedance voltage and so on.
Application Scenarios
1. Electricity Audit (Anti-Theft): Verify the actual capacity of user transformers to combat electricity theft where users install transformers with lower capacity than their actual demand.
2. Transformer Acceptance and Quality Inspection: Conduct capacity verification on newly purchased or repaired transformers to prevent suppliers from substituting inferior products or falsely labeling capacities.
3. Capacity Expansion & Asset Management: Verify the accuracy of nameplate capacities on aging transformers to inform decisions on capacity upgrades or asset retirement.
4. Failure Analysis: Following transformer failures, validate whether the rated capacity matched operational requirements and analyze whether damage resulted from prolonged overloading.
Features & Advantages
Main Features:
- We can measure a variety of distribution transformer, power transformer capacity instead of the additional extra power. It is more convenient and efficient.
- Combined with the external power source, voltage, current regulator equipment etc, it can measures various transformer parameter such as no-load current, no-load loss, impedance voltage, load loss and so on.
- Characteristic test of transformer, test range is wide,flexible configured.only through the simple connection to current transformer and voltage transformer, test scope can be enlarged to high-grade power transformer.
- Short-circuit the terminals of cable,humanization design,with lock,easy connected to fasten units of transformation.
- Measure the transformer load current, load loss, short-circuit voltage, short circuit (load)losses, capability.
- Three measurement Methods.
- Do three-phase transformer no-load, load test, the instrument can automatically determine the wiring is correct, and shows three-phase voltage and current vector map.
- Single machine can do the following 100KVA distribution transformer full load current experiment; in one third of the rated current, complete 250KVA distribution transformer load the following test (in one third of the rated current, the instrument can be converted to load loss under rated current parameters, the machine is mainly used in the test bed with integrated supporting the use of transformers.
- All the related test results are automatically corrected. Instrument can automatically such as: the waveform correction, temperature correction, non-rated voltage correction,calibration, and other non-rated current correction, so that more accurate test results.
- 320x240 large screen, high brightness LCD display, full Chinese menu and operations to achieve prompt and friendly man-machine dialogue, touch buttons make the operation more convenient, wide LCD with brightness adjustment, can be adapted to the various summer and winter season.
- Comes with real-time clock, automatically recording test date, time, the preservation of favorable results, management.
- Panel-type thermal printer, the scene quickly print test results.
- Data (test sample set, the measurement results, the test of time, etc.) with power-down storage and browsing features, you can store 500 set of experimental results with computer on-line data transfer.
- Allows an external voltage transformer and current transformer for extended range of measurement, any measurable parameter is the test product.
Application Conditions
Environmental Conditions: Weather: Rain-free, fog-free, dry air.
Temperature: Preferably within the range of -10°C to 40°C.
Humidity: ≤ 80% RH.
Location: Free from severe vibration and strong electromagnetic interference.
Additional Information
- Core Component: Microprocessor (CPU);Touchscreen/Display; Voltage/Current Sampling Circuit; High-Precision ADC (Analog-to-Digital Converter); Test Cables and Clamps; Overcurrent/Overvoltage Protection Circuit; Rechargeable Lithium Battery; Power Management Circuit; Internal Memory; Communication Interface (USB/Bluetooth);Built-in Transformer Parameter Database.
- The maximum voltage is up to 750V and the maximum current is up to 100A range with protection circuit in it,when you make the characteristic test of transformer.don't worry the precision and damage of the instrument due to in-proper shift.
- The voltage and current range can be very flexible and easy to expand by connecting the external CT or VT
- It has large screen, high brightness LCD display, English menu and operation tips, friendly man-machine interface and wide temperature tolerance, brightness adjustable type LCD screen, which can adapt to the different temperature.
- Thermal sensitive printer is set inside the instrument,it can easily print on site.
Maintenance FAQs
Hot Tags: transformer capacity tester, China transformer capacity tester manufacturers, factory
Technical Specifications
1.The output range of built-in battery
Voltage:0~10V
Current:0~10A
2. The input range of characteristic test power source
Voltage:0~750V
Current:0~100A
3. Accurate of test
Voltage, current:±0.2%
Power:±0.5%(CosΦ>0.1), ±1.0%(0.02<CosΦ<0.1)
4. Working temperature: -20℃~+60℃
5. The requirement of charger
Electric supply: AC160V~265V
Adapter output: 12.6V 1000mA
6. Insulation
⑴ Insulation resistance between capacity , voltage, current to enclosure ≥100MΩ
⑵ bear the 2kV power frequency (effective value) between the
input power and machine enclosure, testing time is 1 minute.
7. Volume: 32cm×25cm×12cm
8. Weight: 2.5KGS