Product Overview & Applications
The HMCJ-400kV/20kJ Lightning Impulse Voltage Generator adopt epoxy pillar tower structure, the stage voltageis 100 kV. lmpulse voltage generator hasadvanced technical index, compact structureand beautiful appearance.
Application:
1. Power Equipment Manufacturing: Primary test subjects: Power transformers, high-voltage switches, instrument transformers, insulators, surge arresters, cables, etc.
2. Transmission and Distribution Systems (Power Companies): Primary test subjects: Critical operational equipment (e.g., transformers), new transmission line designs, faulty equipment.
3. Rail Transit (High-Speed Rail/Subway): Primary test subjects: Traction transformers, onboard converters, catenary insulation equipment.
4. Renewable Energy (Wind/Solar): Primary Test Subjects: Wind turbines, solar inverters, transformers in step-up substations.
5. Research & Testing Institutions: Primary Test Subjects: Novel insulating materials, prototype new equipment.
6. Aerospace & Defense: Primary Test Subjects: Power supply components for aircraft electrical systems, radars, and communication equipment.
Key Features & Advantages
1.Complete equipment and wide voltage levels in the whole set of device , voltage capacity series is complete, perfect in shape and function.
2.Successful development of No partial discharge epoxy insulator ,Small electric inductance in the return circuit of the impulse voltage generator.
3.Simple in operation, Convenient in wave adjustment , excellent in synchronization performance and reliable in motion.
4.High automation and strong anti-interference capacity.
Operating Conditions
1.Not more than 1000 meters above sea level;
2.The ambient temperature is -10℃ ~ +45℃, and the relative humidity is no more than 90%.
3. Free of dust and corrosive gases;
4. The generator body should be reliably grounded nearby, and the grounding grid should have low grounding resistance (below 0.5 ohm) and good impact characteristics.
Maintenance & Troubleshooting (FAQ)
Q: Is operating this equipment complex? What environment is required?
A: Operation requires specialized training. It is typically installed in a high-voltage test hall equipped with comprehensive shielding, grounding, and safety interlock systems to ensure operator safety and measurement accuracy.
Q: What does the standard configuration include? What additional purchases are required?
A: The standard configuration typically includes the generator unit, charging unit, and basic control console. Additional configurations are usually required: Divider (for precise high-voltage measurement);Digital impulse measurement system (for waveform recording and analysis);
Dedicated test software, etc.
Hot Tags: 400kv/20kj lightning impulse voltage generator, China 400kv/20kj lightning impulse voltage generator manufacturers, factory, 1800kV 180kJ Lightning Impulse Voltage Generator, 200kA Impulse Current Generator, 300kV 20kJ Lightning Impulse Voltage Generator, 5600kV Lightning Impulse Voltage Generator, 600kV 30kJ Lightning Impulse Voltage Generator, lightning impulse voltage generator
Technical Specifications
-Rated nominal voltage:400kV
-Rated voltage:100kV
-Rated energy: 20kJ
-Total impulse capactiance:0.25uF
-Single-stage impulse capacitor: 2μF/50kV×2(total 4pcs)
-Load capacitance: 300~3000PF
-Rated nominal value:Current 1Aac,5Aac;
-Voltage 100Vac,150Vac,300Va
-Input overload:Continuous current: 2 times Instantaneous current: 10 times / 5 seconds Instantaneous voltage: 2 times / 30 seconds
-Input load:Current transformer:≤0.2VA;Voltage transformer:≤0.1VA