Standard Pulse Current Generator

Standard Pulse Current Generator

The 100kA Impulse Current Generator is a specialized testing system designed to generate standardized impulse current waveforms. This equipment simulates lightning strikes (8/20μs waveform) and performs surge protective device (SPD) operational tests (10/350μs waveform), essential for evaluating electrical/electronic systems' surge withstand capabilities.
Send Inquiry
Description
Technical Parameters

Product Overview & Applications

 

04

Product Overview

A 100kA pulse current generator is a specialized testing system designed to generate standardized pulse current waveforms. The device simulates lightning strikes (8/20 μ s waveform) and performs surge protection device (SPD) operation tests (10/350 μ s waveform), which is crucial for evaluating the surge withstand capability of electrical/electronic systems.

Key applications:
Laboratory testing and quality control
SPD certification (compliant with IEC/GB/VDE/ANSI standards)
Anti surge verification of power equipment
Research and academic institutions

 

Technical Specifications

 

Parameter

Value

Input Power

2 - phase AC 380V±10%, 50Hz, 20kVA

Max Charging Voltage

DC 45kV

Total Energy Storage

300kJ

8/20μs Waveform

100kA±10% (T1:8μs±10%, T2:20μs±10%)

10/350μs Waveform

50kA±10% (T1:10μs±10%, T2:350μs±20%)

Residual Voltage

≤5kV

Overshoot

≤5% of peak value

Reverse Current

≤20% of peak value

 

1.Input voltage: AC 2 Phase, 50HZ, 380V/50kV/20kVA

2.The current waveform is 8/20μs. The residual voltage of SPD is not more than 5kV;

The allowable error of the waveform:

- Ipeak:±100kA ±10%;

- T1: 8μs ±10%;

- T2: 20μs ±10%.

3.The current waveform is 10/350μs. The residual voltage of SPD is not more than 5kV;

Allowable error of waveform:

- Ipeak:±50kA ±10%;

- T1: 10μs ±10%;

-T2: 350μs ±20%.

4.The small overshoot or amplitude of the shock waveform should not be greater than 5% of the peak. The current value of the reverse should not be greater than 20% of the peak value; Maximum charging voltage: DC45kV, maximum charging current 0.5A;

 