Wuhan Goldhome Hipot Electrical Co., Ltd. is one of the leading manufacturers and suppliers of ct pt characteristics tester in China. With abundant experience, our factory offer high quality customized products made in China with competitive price. Welcome to contact us for quotation.
Products video
HMCTP 100P CT PT Analyzer Display Video
Test results
The test result interface as shown in figure:

Fig 1 The test result interface
For different classes of CT and measured items,the test result will be different too,details as table 2.3:
Table 2.3 CT test results description
|
result |
description |
P |
TPY |
M |
PR |
PX |
TPS |
TPX |
TPZ |
|
|
Load |
Actual load |
unit:VA,CT secondary measure actual load |
√ |
√ |
√ |
√ |
√ |
√ |
√ |
√ |
|
Power factor |
Power factor of actual load |
√ |
√ |
√ |
√ |
√ |
√ |
√ |
√ |
|
|
impedance |
unit:Ω,CT secondary measure secondary impedance |
√ |
√ |
√ |
√ |
√ |
√ |
√ |
√ |
|
|
Resistance |
resistance(25℃) |
unit:Ω,CT secondary measure secondary resistance |
√ |
√ |
√ |
√ |
√ |
√ |
√ |
√ |
|
resistance(75℃) |
unit:Ω,Convert to resistance under 75℃ |
√ |
√ |
√ |
√ |
√ |
√ |
√ |
√ |
|
|
excitation |
knee voltage and knee current |
unit:V and A,According to standard definition,when knee voltage increase 10%,knee current increase 50%. |
√ |
√ |
√ |
√ |
√ |
√ |
√ |
√ |
|
Unsaturated inductance Lu |
unit:H,The average inductance of linear section for excitation curve |
√ |
√ |
√ |
√ |
√ |
√ |
√ |
√ |
|
|
remanence coefficient Kr |
ratio of magnetism and magnetic |
√ |
√ |
√ |
√ |
√ |
√ |
√ |
√ |
|
|
Second time constant Ts |
unit:s,the time constant of CT's second connect rated burden |
√ |
√ |
√ |
√ |
√ |
√ |
√ |
√ |
|
|
limiting e.m.f Eal |
unit:V,calculation limit e.m.f. according to the CT nameplate and resistance under 75℃ |
√ |
√ |
√ |
√ |
√ |
√ |
|||
|
composite error
|
limiting e.m.f or the composite error of rated knee potential |
√ |
√ |
√ |
√ |
|
||||
|
Peak transient error
|
Peak transient error of limiting e.m.f |
√ |
√ |
√ |
||||||
|
ALF |
actual ALF |
√ |
√ |
|
||||||
|
Instrument security coefficient |
actual instrument security coefficient |
√ |
|
|||||||
|
Symmetrical short-circuit current multiples Kssc |
actual symmetrical short-circuit current multiples |
√ |
√ |
√ |
√ |
|||||
|
transient dimensioning factor |
actual transient dimensioning factor |
√ |
√ |
√ |
||||||
|
calcuated coefficient Kx |
actual calcuated coefficient |
√ |
|
|||||||
|
Rated knee potential Ek |
√ |
|
||||||||
|
Ie corresponding with Ek |
The actual excitation current corresponding with rated knee potential |
√ |
|
|||||||
|
Rated voltage Ual |
The rated equivalent second limit voltage |
√ |
|
|||||||
|
Ial corresponding with Ual |
The actual excitation current corresponding with the rated equivalent second limit voltage |
√ |
|
|||||||
|
Ratio |
Ratio |
Actual current ratio under rated burden |
√ |
√ |
√ |
√ |
√ |
√ |
√ |
√ |
|
Turns ratio |
The ratio of actual secondary winding and primary winding |
√ |
√ |
√ |
√ |
√ |
√ |
√ |
√ |
|
|
Ratio difference |
The current errors under rated load |
√ |
√ |
√ |
√ |
√ |
√ |
√ |
√ |
|
|
Phase difference |
The D-value of phase under rated load |
√ |
√ |
√ |
√ |
√ |
√ |
√ |
√ |
|
|
Polarity |
There're two polarity relationship for primary CT and secondary CT: Positive and Negative |
√ |
√ |
√ |
√ |
√ |
√ |
√ |
√ |
|
|
Turn ratio error |
The relative error between measured trun ratio and rated turn ratio |
√ |
√ |
|
||||||
Note: "√" expressed the need for settings that do not need to set up a blank
II.Error data
Selecting the error data will show 5% and 10% error cases, the relationship of rated primary current multiple and the maximum burden is shown as Fig 2.5. These data is calculated according to the actual excitation. The calculation Method is given in appendix B.

Fig 2 5% error data interface
product Details
| Product | Cross Weight | Package Dimension |
| host and Accessory Box | 32kg | 480*270*720mm(L*W*H) |
Included Accessories:
| No. | Name | QTY |
| 1 | Test line(5m Red black) | 1 |
| 2 | Test line(5m Yellow black) | 1 |
| 3 | Test line(20m Green black | 1 |
| 4 | Ground wire(5m) | 1 |
| 5 | power cord(1.5m) | 1 |
| 6 | Terminals | 12 |
| 7 | Alligator clip | 12 |
| 8 | Fuse(10A) | 5 |
| 9 | printer paper | 2 |




Hot Tags: CT PT Characteristics Tester, China CT PT Characteristics Tester manufacturers, factory