270kVA Variable Frequency Resonant Test System

270kVA Variable Frequency Resonant Test System

The HMCXZ-270KVA/270kV system primarily consists of a frequency-converted power supply, an excitation transformer, reactors, and a capacitive voltage divider. It is designed and manufactured specifically for AC withstand voltage testing of 10kV, 35kV, and 110kV cables and their associated systems. The reactors are designed as multiple separate units, enabling the system to meet both the testing requirements for high-voltage, low-current equipment and the AC withstand voltage testing requirements for low-voltage applications such as 10 kV cables. This makes it an ideal withstand voltage testing device for high-voltage testing departments as well as power installation, maintenance, and testing engineering units.
Send Inquiry
Description
Technical Parameters

Wuhan Goldhome Hipot Electrical Co., Ltd. is one of the leading manufacturers and suppliers of 270kva variable frequency resonant test system in China. With abundant experience, our factory offer high quality customized products made in China with competitive price. Welcome to contact us for quotation.

 

Product Overview & Applications

 

The HMCXZ-270KVA/270kV system primarily consists of a frequency-converted power supply, an excitation transformer, reactors, and a capacitive voltage divider. It is designed and manufactured specifically for AC withstand voltage testing of 10kV, 35kV, and 110kV cables and their associated systems. The reactors are designed as multiple separate units, enabling the system to meet both the testing requirements for high-voltage, low-current equipment and the AC withstand voltage testing requirements for low-voltage applications such as 10 kV cables. This makes it an ideal withstand voltage testing device for high-voltage testing departments as well as power installation, maintenance, and testing engineering units.

 

Key Features & Advantages

 

1) Placed way: the placement of variable frequency power for longitudinal and transverse, especially suitable for field operation and observe.

2) Shockproof protection: internal and external have special damping rubber support foot and protect aluminum boxes, which can effectively slow motion and lifting the bumpy transport the shock. Ensure the inverter power long-term stability and reliability.

3) Parameter display: touch or external mouse LCD interface display system.

Can show resonance voltage (namely test before setting goals voltage), test frequency, measure frequency, low-pressure voltage, low voltage electric current, voltage time, over-voltage protection, over-current protection, flash winding protection, phase booster and stage timing, operation mode switch, capacitor, inductance, frequency swap calculation, parameters, still can show inquiry on frequency curve, voltage curve can intuitivey judgment when trials resonance frequency accurately and stability.

4) Parameter Settings: big screen touch LCD backlit and external mouse directly in completing various parameters Settings. But on the initial frequency, termination frequency, starting voltage, phase booster and timing, measuring bleeder variable ratio, incentive change ratio, over-voltage protection, over-current protection, flash winding protection, test mode, capacitance inductance frequency swap calculation, parameter setting tips, and help parameters Settings or choice.

5) Test mode: touch screen and external mouse operation, there is automatic and semi-automatic, manual three operating status. With pressor, tuning (including manual, automatic), subsection pressurized and timing, running status, pattern switching, troubleshooting tips, capacitance inductance frequency swap computing functions, etc.

6) Protection function and information clew: having high-pressure over-voltage protection, low-pressure over-current, over-current protection, as well as detuning protection, zero, shem winding protection, emergency stop, undervoltage protection multiple protection function.

7) Automatic voltage function: system according to the test voltage or manually set of automatic tracking and boost results, stable test voltage, voltage stability can amount to 1.0%.

8) FM range and frequency resolution all can set: FM range set:30~300Hz,45~100Hz,200-300Hz, on-demand setting, can accelerate tuning process; The frequency resolution, according to the needs, presetting 0.1 Hz,efficiency and tuned in tuned balance between accuracy obtained optimization.

9) Frequency adjustment is divided into thick harmonic fine tuning, and automatic resonant point, guarantee for trials in the whole experiment resonant frequency process does not happen drift.

10) Storage measuring datas and print.

 

Technical Parameters

 

- Rated Capacity: 270kVA;

- Output Voltage: 0-270KV

- Output frequency: 30-300Hz;

- Input Power: 220V/380V ±10 %single phase, 50Hz

- Waveform distortion rate: output voltage distortion ≤ 1%;

- Working time: 30mins under rated load;

Cable testing: continuous 60 minutes under rated load;

- Temperature rise: ≤65Kunder rated load;

- Working Temperature: -15℃~+45℃

- Quality factors: Q ≥ 50;

Cable testing Q ≥ 30 (depend on load).

- Stability: Over-current/over-voltage/Flashover protection;Auto Time;Touch Screen;

- Accuracy: RMS 1.5

Hot Tags: 270kVA Variable Frequency Resonant Test System, China 270kVA Variable Frequency Resonant Test System manufacturers, factory, ac resonance equipment testing system for ac resonance monitoring device testing, ac resonance device testing system, ac resonance motor testing system for ac resonance performance testing system, ac resonance breaker testing system for ac resonance inductance testing system, ac resonance equipment testing instrument for fuses, ac resonance assembly testing system