Current Transformer On-Site Calibrator

Current Transformer On-Site Calibrator

Goldhome's on-site current transformer tester is developed using advanced testing technology, large-scale electronic circuit design, and in compliance with relevant national standards. It addresses the issues of high workload and cumbersome operations associated with on-site verification of current transformers, while offering reliable performance and powerful functionality.
Send Inquiry
Description
Technical Parameters

Product Overview

 

HMCT-H03

Goldhome's on-site current transformer tester is developed using advanced testing technology, large-scale electronic circuit design, and in compliance with relevant national standards. It addresses the issues of high workload and cumbersome operations associated with on-site verification of current transformers, while offering reliable performance and powerful functionality.

 

Products Features

 

  • Tests are conducted using a power supply with a frequency close to power line frequency to prevent on-site power line electromagnetic radiation and series interference.
  • The measurement range is wide, extending from 5A/5A to 31,500A/5A or 5A/1A to 6,300A/1A.
  • Includes functions for testing current transformer turns ratio and secondary winding resistance.
  • Features an 800×600 high-resolution large-screen TFT color LCD touchscreen with a user-friendly interface and operation design; touchscreen-assisted operation makes usage more convenient and efficient.
  • Utilizes precise software algorithms to further enhance the accuracy of measurement data.
  • Intelligently detects external wiring conditions and alerts users to wiring errors, incorrect turns ratios, and polarity errors.
  • It automatically rounds test data to the nearest integer and determines whether it falls within tolerance limits. Data outside tolerance limits is displayed in orange, and a "Out of Tolerance" message appears in the lower-right corner of the window, providing an intuitive and clear view of the transformer's performance characteristics.
  • It is the first in China to offer the capability to simultaneously test both the turns ratio and polarity of voltage transformers.

HMCT-H04

 

Products parameters

 

Rated primary current range for a current transformer with a secondary current of 5 A

5

7.5

10

15

20

25

30

40

50

60

75

80

100

120

150

160

200

250

300

315

400

500

600

630

750

800

1000

1200

1250

1500

1600

2000

2500

3000

3150

3200

4000

5000

6000

6300

Rated primary current range for a current transformer with a secondary current of 1 A

5

7.5

10

15

20

25

30

40

50

60

75

80

100

120

150

160

200

250

300

315

400

500

600

630

750

800

1000

1200

1250

1500

1600

2000

2500

3000

3150

3200

4000

5000

6000

6300

Rated Primary Current (A) Number of Turns Through the Core Instrument Primary Current (A)

80

2

40

120

2

60

8000

2

4000

12000

2

6000

Operating range of the current transformer under test: 1%–200%

④ Secondary load: 2.5 VA–300 VA, COSφ = 0.1–1.0

⑤ Accuracy classes of the current transformer under test: 1.0, 0.5, 0.5S, 0.2, and 0.2S

⑥ Measurement error for resistance and admittance: ≤5.0%

Measurement range: R: 0.00 Ω to 20.0 Ω

Y: 0.000 mS to 100.0 mS

2. Voltage Transformer Calibrator Section

Turns ratio test range: 1 kV–500 kV

3. Instrument Power Consumption: 20 VA

4. Instrument Accuracy Class: 0.05S

5. Maximum Dimensions (cm): L460 × W375 × H183

6. Weight (kg): 10.0

 

panel Diagram

 

HMCT-H

 

product-46-13

Hot Tags: current transformer on-site calibrator, China current transformer on-site calibrator manufacturers, factory