Product Overview

Goldhome's on-site current transformer tester is developed using advanced testing technology, large-scale electronic circuit design, and in compliance with relevant national standards. It addresses the issues of high workload and cumbersome operations associated with on-site verification of current transformers, while offering reliable performance and powerful functionality.
Products Features
- Tests are conducted using a power supply with a frequency close to power line frequency to prevent on-site power line electromagnetic radiation and series interference.
- The measurement range is wide, extending from 5A/5A to 31,500A/5A or 5A/1A to 6,300A/1A.
- Includes functions for testing current transformer turns ratio and secondary winding resistance.
- Features an 800×600 high-resolution large-screen TFT color LCD touchscreen with a user-friendly interface and operation design; touchscreen-assisted operation makes usage more convenient and efficient.
- Utilizes precise software algorithms to further enhance the accuracy of measurement data.
- Intelligently detects external wiring conditions and alerts users to wiring errors, incorrect turns ratios, and polarity errors.
- It automatically rounds test data to the nearest integer and determines whether it falls within tolerance limits. Data outside tolerance limits is displayed in orange, and a "Out of Tolerance" message appears in the lower-right corner of the window, providing an intuitive and clear view of the transformer's performance characteristics.
- It is the first in China to offer the capability to simultaneously test both the turns ratio and polarity of voltage transformers.

Products parameters
| Rated primary current range for a current transformer with a secondary current of 5 A | |||||||
|
5 |
7.5 |
10 |
15 |
20 |
25 |
30 |
40 |
|
50 |
60 |
75 |
80 |
100 |
120 |
150 |
160 |
|
200 |
250 |
300 |
315 |
400 |
500 |
600 |
630 |
|
750 |
800 |
1000 |
1200 |
1250 |
1500 |
1600 |
2000 |
|
2500 |
3000 |
3150 |
3200 |
4000 |
5000 |
6000 |
6300 |
| Rated primary current range for a current transformer with a secondary current of 1 A | |||||||
|
5 |
7.5 |
10 |
15 |
20 |
25 |
30 |
40 |
|
50 |
60 |
75 |
80 |
100 |
120 |
150 |
160 |
|
200 |
250 |
300 |
315 |
400 |
500 |
600 |
630 |
|
750 |
800 |
1000 |
1200 |
1250 |
1500 |
1600 |
2000 |
|
2500 |
3000 |
3150 |
3200 |
4000 |
5000 |
6000 |
6300 |
| Rated Primary Current (A) | Number of Turns Through the Core | Instrument Primary Current (A) |
|
80 |
2 |
40 |
|
120 |
2 |
60 |
|
8000 |
2 |
4000 |
|
12000 |
2 |
6000 |
Operating range of the current transformer under test: 1%–200%
④ Secondary load: 2.5 VA–300 VA, COSφ = 0.1–1.0
⑤ Accuracy classes of the current transformer under test: 1.0, 0.5, 0.5S, 0.2, and 0.2S
⑥ Measurement error for resistance and admittance: ≤5.0%
Measurement range: R: 0.00 Ω to 20.0 Ω
Y: 0.000 mS to 100.0 mS
2. Voltage Transformer Calibrator Section
Turns ratio test range: 1 kV–500 kV
3. Instrument Power Consumption: 20 VA
4. Instrument Accuracy Class: 0.05S
5. Maximum Dimensions (cm): L460 × W375 × H183
6. Weight (kg): 10.0
panel Diagram

![]()
Hot Tags: current transformer on-site calibrator, China current transformer on-site calibrator manufacturers, factory