Product Overview & Application Scenarios
HM2571B high-end multi-functional clamp earth resistance meter is with USB communication interface, storage data can be uploaded to the computer, through software analysis, report, printing and so on. At the same time, it could test 40A leakage current, increases real-time clock function to display present time, supports multi-parameter on-screen display function, can display grounding resistance and ground leakage current at the same time, which is more practical, convenient and efficient.
Features & Advantages
- Breakthrough in self-test the boot a long time to wait, start immediately into the test.
- Breakthrough relay self-test mode, using the most advanced processing algorithms and digital integration technology.
- Add real-time clock function to display real-time time of present test.
- New design, panel operation with 6 buttons, better performance.
- An increase of sound and light alarm, "beep-beep--beep --" alarm sound.
- Increase the interference signal recognition indicator.
- Add a variety of combination display mode, can choose resistance + current, resistance + time, current + time to display on screen.
- Measure range more large: 0.01Ω-1500Ω,0.001mA-40.0A.
- Stored data: 999 Units. Lower power consumption: Maximum operating current not exceeding 50mA.
- Rechargeable battery makes it more convenient to use.
Application Conditions
1. Environmental Conditions
Operating Temperature: -10°C to +55°C
Relative Humidity: ≤ 80% RH (non-condensing)
Altitude: ≤ 2000 meters
Pollution Degree: 2 (for normal indoor environments)
2. Electrical Conditions of the Grounded System:
System Requirement,Measurement Principle,It cannot measure an isolated, single ground rod.
3.Physical Conditions for Clamping:
Jaw Opening: Must be large enough to fit around the ground conductor or rod. Typical max jaw size is around 32mm.
Conductor Position: The conductor must be centered within the clamp jaws for accurate measurement.
Jaw Cleanliness: The jaw surfaces must be clean and closed completely to ensure a good magnetic circuit.
4.Electromagnetic Environment
Stray Currents: The instrument is designed to filter out power frequency (50/60 Hz) interference. However, strong external magnetic fields from nearby high-current cables can affect accuracy.
Safe Distance: Keep the meter away from live busbars or conductors not involved in the measurement
Maintenance & FAQs
Hot Tags: clamp earth resistance tester, China clamp earth resistance tester manufacturers, factory
Technical Specifications
|
Mode |
Range |
Resolution |
Accuracy |
|
Resistance |
0.010Ω-0.099Ω |
0.001Ω |
±(1%+0.01Ω) |
|
0.10Ω-0.99Ω |
0.01Ω |
±(1%+0.01Ω) |
|
|
1.0Ω-49.9Ω |
0.1Ω |
±(1%+0.1Ω) |
|
|
50.0Ω-99.5Ω |
0.5Ω |
±(1.5%+0.5Ω) |
|
|
100Ω-199Ω |
1Ω |
±(2%+1Ω) |
|
|
200Ω-395Ω |
5Ω |
±(5%+5Ω) |
|
|
400-590Ω |
10Ω |
±(10%+10Ω) |
|
|
600Ω-880Ω |
20Ω |
±(20%+20Ω) |
|
|
900Ω-1500Ω |
30Ω |
±(25%+30Ω) |
|
|
Current |
0.00mA -9.95mA |
0.05mA |
±(2.5%+2mA) |
|
10.0mA -99.0mA |
0.1mA |
±(2.5%+5mA) |
|
|
100mA -300mA |
1mA |
±(2.5%+20mA) |
|
|
0.30A-2.99A |
0.01A |
±(2.5%+0.1A) |
|
|
3.0A-9.9A |
0.1A |
±(2.5%+0.3A) |
|
|
10.0A-19.9A |
0.1 A |
±(2.5%+0.5A) |
|
|
20.0A-40.0A |
0.1 A |
±(3%+1A) |