Primary Current Injection Test System

Primary Current Injection Test System

The HMSLQ 5000A High Current Injection Test System is primarily employed for high current temperature rise testing of electrical equipment such as distribution boxes, busbars, and switches. The system supports customisable long-term operation modes and is equally suited for short-duration or intermittent work. As essential equipment for power stations, substations, distribution stations, electrical.....
Send Inquiry
Description
Technical Parameters

Product  Video

 

HMSLQ 5000A Primary Current Injection Test System Display Video

 

 

Products Description

 

5000A 03

The HMSLQ 5000A High Current Injection Test System is primarily employed for high current temperature rise testing of electrical equipment such as distribution boxes, busbars, and switches. The system supports customisable long-term operation modes and is equally suited for short-duration or intermittent work. As essential equipment for power stations, substations, distribution stations, electrical manufacturers, research institutions, and laboratories, it delivers stable and reliable performance with straightforward maintenance.

 

Technical Specifications

 

1. Control unit (1 unit)

1) Input Voltage:380V/3 phase

2) Capacitance:120kVA

3) Input Current:182.3A

4) Output Current:5000A

5) Indicator of Output current:5000A

6) Input voltage indicator: 450V

7) Meter Accuracy:0.5(Digital)

8) Over-current setting: 5000A (three phase/single phase shift)

9)Over-current trip releasing time: 7ms

10) Timer range: 0~999S,M,H for changing

11) Working time: ≤8 hours continuously at 5000A

12) Cooling method::Natural strong cooling

2. Current up transformer(1 unit)

1) Input Voltage:0~600V/ single phase

2)Input Current:0~100A

3) Capacitance:103.9kVA

4) Output Voltage:0~6.9V (phase voltage);

0~12V (line to line voltage-open circuit)

5)Output Current:0~5000A

6) Current Transformer:HL1-5000A/5A (3 units)

7) Accuracy of Current Transformer:0.5

8) Working Time:≤8 hours at 5000A

9) Cooling method::Natural Strong Cooling

3. Electric induction voltage regulator (3 units)

1)Input Voltage:0~380V/ single phase

2)Input Current:0~105.2A

3) Capacitance:3*40kVA

4) Output Voltage:25~650V

5)Output Current:0~61.5A

6) Working time:≤8 hours at 5000A

7)Cooling method::Oil circulation cooling

5000A 05

 

 

FAT pictures

 

Factory Release Test for HMSLQ-5000A Primary Current Injection Test System

 

5000A

Hot Tags: primary current injection test system, China primary current injection test system manufacturers, factory