Anti-interference Megohmmeter Insulation Test Meter

Anti-interference Megohmmeter Insulation Test Meter

HM2672 Anti-interference megohmmeter insulation test meter is research and manufacture to solve the evaluation of electrical insulation quality of HV transformers, motors, generators, long-distance high-voltage cables, tubular busbars, etc. under strong interference from high-voltage substations and power plants. It is especially suitable for large-capacity over 110kv Test site with strong sexual interference.
Send Inquiry
Description
Technical Parameters

Wuhan Goldhome Hipot Electrical Co., Ltd. is one of the leading manufacturers and suppliers of anti-interference megohmmeter insulation test meter in China. With abundant experience, our factory offer high quality customized products made in China with competitive price. Welcome to contact us for quotation.

 

Products Description

 

megohmmeter insulation test meter-01

 

HM2672 Anti-interference megohmmeter insulation test meter is research and manufacture to solve the evaluation of electrical insulation quality of HV transformers, motors, generators, long-distance high-voltage cables, tubular busbars, etc. under strong interference from high-voltage substations and power plants. It is especially suitable for large-capacity over 110kv Test site with strong sexual interference.

The meter has the function of measuring separately, measuring absorbing ratio and polarization index, and can measure each value at one time. It is a kind of insulation resistance measuring instrument with convenient use, comprehensive function and wide measuring range.

 

 

 

Technical Specifications

 

megohmmeter insulation test meter-0

●Insulation resistance: 50M (between measuring circuit and shell)

●Withstand voltage: AC 10kV 50Hz 1min (between measuring circuit and shell)

●Working temperature and humidity: -10℃ ~ +50℃ 85%RH

●Storage temperature and humidity: -15℃ ~ +55℃ 90%RH

● Charging power supply: 220V±10%, 50/60 HZ

● Battery power supply: 16V Li-ion rechargeable battery, 2600mAH or charging while measuring,without affecting the test accuracy.

● Size:27 ×22 ×15cm

● Weight: 3kg

● Test voltage accuracy: 100% to 110% of the nominal value

● Voltage measurement accuracy: 5%+10V

● Short circuit current: 7-10mA.

●Display mode: digital and analog pointer dual display.

 

HM2672

 

 

1)Range and Accuracy

Current Max Accuracy

 

±(1.5%+0.5mA)

Data Storage

999 Sets

 

Interface

USB interface, software monitoring, data upload computer, dynamic display

Self-test Time

≤1s,Boot into the test mode quickly

Working Current

≤50mA

Operation Button

6 soft keys, better performance

Communication Cable Length

1.5m(USB Cable)

Clock Function

Display hour and minute

 

Audible Alarm

"Beep--beep--beep--" alarm sound, press the AL key to

turn on and off; LCD alarm flashing indication

Alarm Threshold

Setting Range

Resistance:1-199Ω;

Current: 1-499mA

Power Supply

3.7VDC(Rechargeable lithium batteries2600mAh)

 

Auto Power Off

The instrument flashes 30S after 5 minutes without any

operation, and then auto power off

Working

Environment

 

-20℃-55℃; 10%RH-90%RH

LCD Size

47mm×28.5mm

Clamp Size

65mm×32mm

Clamp Opening Size

 

32mm

Tester Weight

1160g

Meter Size

285mm×85mm×56mm

Battery Cover

Screw knot fixation

Protection Level

Double insulation

Structural Features

Clamp CT

Shift

Auto Shift

External Magnetic

Field, Electric Field

 

 

<40A/m;<1V/m

Single Measurement Time

 

0.5s

Resistance Measurement Frequency

>1KHz

Measured Current

Frequency

 

50/60Hz Auto

 

Products features

 

  • Accordance with IEC standards, output voltage:250v,500v 1000v,2500v,5000v.
  •  The Anti-interference megohmmeter insulation test meter has an automatic calibration function,automatically calibrate accuracy before test.
  • equipped with self-check function can automatically detect if the measured circuit is normal.
  • With the function of measuring the live voltage of the actual test goods , can test leakage current,automatic discharge.
  •  R15S, R60S and R10min values can be automatically measured and saved, automatically display polarization index (PI), inductance absorption ratio (DAR) and test time .
  • Superior anti-interference performance,even if the interference current reaches 2mA,The HM2672 5000V insulation resistance tester still guarantees test accuracy.
  • double display with analog pointer and the digital, the number reflects the accuracy of the test object insulation resistance , and the analog pointer can reflect the dynamic change of the insulation resistance during the test.
  • Short circuit protection, the test is stopped when the leakage current is large in the short circuit state.

 

precautions for use

 

●Before the test connection, it must be ensured that the test product has been completely discharged and isolated.

●The instrument must be operated by suitably trained personnel.

●When testing, never touch the test circuit.

●Confirm that the tested product is safely grounded, and the tested product does not carry strong current.

●Confirm that the E terminal (grounding terminal) of the meter is grounded.

●Confirm that the battery is sufficiently charged. If the battery is undervoltage, it will not be able to boot.

●Press the on/off button for about 2 seconds, the LCD screen displays the working interface.

●The LCD screen displays "self-checking" and it is in the state of "waiting for measurement" after the self-checking is completed.

●Voltage selection button to select the voltage range, touch the "Start/Stop" button, the high voltage is turned on, the LCD screen displays "Measuring", there is high voltage output at the E and L terminals of the meter, and the buzzer sounds continuously. Please pay attention to safety ! Press the "Start/Stop" button again to stop the measurement and display "Waiting for measurement"

●After the test is completed, touch the "Start/Stop" button, and press the Start/Stop button to stop boosting. When the automatic discharge of the instrument is less than 0v (after the danger of electrification disappears), the wire can be disconnected.

 

Faults and phenomena

 

frequent phenomenon

Description and disposal

There is no display on the LCD screen after power on.

Long press the power button

If the battery power is insufficient, plug in AC220V to charge the battery, the power indicator should be flashing, and the power indicator should be on when charging is complete.

No data is displayed during the test.

Use a multimeter to check whether the L and E test leads are normal.

After L and E are short-circuited, it will display 0, open circuit display >10T

There may be poor contact between the test line and the tested product.

The insulation resistance value of the tested product exceeds the upper limit of the meter range or is open.

Hot Tags: anti-interference megohmmeter insulation test meter, China anti-interference megohmmeter insulation test meter manufacturers, factory