Wuhan Goldhome Hipot Electrical Co., Ltd. is one of the leading manufacturers and suppliers of ac variable frequency resonant test set (2400 kva, 600 kv) in China. With abundant experience, our factory offer high quality customized products made in China with competitive price. Welcome to contact us for quotation.
Products Video
Products Description
HMCXZ-2400kVA/600kV Variable Frequency Resonant Test Set (2400 kVA / 600 kV)
2400 kVA · 600 kV at 4 A or 300 kV at 8 A · 20–300 Hz · four units
A complete series resonant AC withstand set for 110 kV and 220 kV GIS, short cable and power system equipment. A 120 kW variable frequency supply, a 120 kVA excitation transformer with three output windings, two 1200 kVA oil reactors and a 600 kV / 1000 pF divider - quoted and shipped as one matched circuit.

Capacity
2400 kVA
Max voltage
600 kV
Supply unit
120 kW
Reactors
2 × 1200 kVA
Products Description
The reactors are deliberately built as separate units rather than one block. That is what lets the same purchase serve high-voltage, low-current specimens and lower-voltage, higher-current ones: parallel the two 300 kV reactors for 300 kV at 8 A, or series them for 600 kV at 4 A. Capacity stays 2400 kVA
2400 kVA from a 120 kW feed
The supply covers only the active losses of a resonant circuit, so the power needed is 1/Q of the test capacity - three-phase 380 V, 50 Hz is enough.
Four units, one circuit
Supply, excitation transformer, reactors and divider are specified against the same duty and delivered with one terminal schedule for the whole set.
Current falls at breakdown
When the specimen fails the circuit detunes and loop current drops to 1/Q; the fault point is not burned away by a follow-through current.
20–300 Hz tuning
Frequency instability of 0.05% or less, voltage resolution 0.01 kV, and a sweep that can start and stop wherever you set it, up or down.
Three-stage withstand program
Each stage carries its own voltage and time. Cable work usually needs one stage; the other two are there when a specimen needs them.
Records by test time
Data stored under the testing time as the record number, printable from the controller and exportable over USB for the test file.
Specifications
|
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
System
Variable frequency supply - CHXB-120kW
Excitation transformer and reactors
Divider, environment and safety
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Components
HMCXZ-2400kVA/600kV Variable Frequency Resonant Test Set
Variable frequency power supply
CHXB-120kW/0.38kV · with console
- 0–400 V single phase, 20–300 Hz, 300 A
- Voltage resolution 0.01 kV, distortion ≤1%
- Panel: Print Power, E-Stop, Reset, Power Indicator
01
Excitation transformer
120 kVA / 5 kV / 10 kV / 20 kV / 0.4 kV
- 400 V single-phase input from the supply cabinet
- 5 kV, 10 kV, 20 kV outputs chosen per test
- Oil type; HV tail must be grounded
02
High voltage reactors
DK-1200kVA/300kV · 2 pcs
- 1200 kVA, 300 kV, 4 A, 300 H each
- Q above 50 at 45 Hz, oil immersed
- Input on the base, output on the top
03
Capacitor voltage divider
FCR-600kV/1000pF
- 1000 pF, dielectric loss below 0.15%
- Accuracy 1.5, ratio by console serial number
- Two grounding terminals, both to be earthed
04
Console and control
7-inch true-colour touch screen
- 32-bit RISC CPU with a 7-inch touch screen showing resonance, boost and timing curves
- Live true-RMS feedback of HV current, HV voltage and LV current
- Calculates the resonant frequency from reactor inductance and specimen capacitance
05
Four functions
Set
Start and termination frequency, tuned voltage, manual withstand time, inductance, capacitance, three stages of voltage and time, alarm voltage, alarm current, flashover factor.
01
Man
Start, Tune, voltage step up and down, Timing, Stop. Close only after the voltage has returned to zero.
02
Auto
The sequence runs from the parameters without operator action; the operator monitors the equipment.
03
File
Query stored data by testing time, print from the controller after Print Power, or export to USB inserted before the test.
04
Notices
- Two or more qualified high-voltage test operators; read the manual and complete repeated operation training first
- Grounding resistance below 2 Ω - a higher value may damage the series resonance test system
- Do not stand the reactors on metal or metal-mesh prefabricated ground: resonance may not be found and eddy currents can burn the coil
- Connect and disconnect correctly; do not pull test leads at will from a live terminal, and check every connecting wire before power-up
- Ground the housing pole as well as the supply cord earth; both divider grounding terminals must be earthed
- Cut off the control supply of the variable frequency power source after every test, before the next one or at the end of the shift
- Do not operate with covers removed, in a humid environment or in an explosive environment; keep the surface clean and dry
- Use only the power cord supplied for this product, and observe the rating of every terminal.
FAQ
Q: Can one set do both 300 kV and 600 kV testing?
A:Yes. The two reactors are arranged in parallel for 300 kV at 8 A, or in series for 600 kV at 4 A. Rated capacity stays at 2400 kVA, and the excitation transformer offers 5 kV, 10 kV and 20 kV outputs to suit the arrangement.
Q: What is the delivery and duty position?
A: Each unit is rated for continuous operation for 60 minutes at rated load, followed by 60 minutes of rest, with a temperature rise of no more than 65 K. The supply unit runs continuously for 60 minutes at rated capacity, with component temperature within 65 K and noise below 50 dB.
Q: Where can the reactors be sited?
A:Each unit is rated for continuous operation for 60 minutes at rated load, followed by 60 minutes of rest, with a temperature rise of no more than 65 K. The supply unit runs continuously for 60 minutes at rated capacity, with component temperature within 65 K and noise below 50 dB.