AC Variable Frequency Resonant Test Set (2400 KVA, 600 KV)

AC Variable Frequency Resonant Test Set (2400 KVA, 600 KV)

Rated capacity 2400 kVA Rated voltage 300 kV / 600 kV Rated current 8 A / 4 A Input supply Three-phase 380 V, 50 Hz Working frequency 20–300 Hz Duty 60 min on, 60 min rest
Send Inquiry
Description
Technical Parameters

Wuhan Goldhome Hipot Electrical Co., Ltd. is one of the leading manufacturers and suppliers of ac variable frequency resonant test set (2400 kva, 600 kv) in China. With abundant experience, our factory offer high quality customized products made in China with competitive price. Welcome to contact us for quotation.

 

Products Video

                                 

 

 

Products Description

 

HMCXZ-2400kVA/600kV Variable Frequency Resonant Test Set (2400 kVA / 600 kV)

 

2400 kVA · 600 kV at 4 A or 300 kV at 8 A · 20–300 Hz · four units

A complete series resonant AC withstand set for 110 kV and 220 kV GIS, short cable and power system equipment. A 120 kW variable frequency supply, a 120 kVA excitation transformer with three output windings, two 1200 kVA oil reactors and a 600 kV / 1000 pF divider - quoted and shipped as one matched circuit.

 

logo6

Capacity

2400 kVA

 

Max voltage

600 kV

 

Supply unit

120 kW

 

Reactors

2 × 1200 kVA

 

Products Description

 

The reactors are deliberately built as separate units rather than one block. That is what lets the same purchase serve high-voltage, low-current specimens and lower-voltage, higher-current ones: parallel the two 300 kV reactors for 300 kV at 8 A, or series them for 600 kV at 4 A. Capacity stays 2400 kVA

2400 kVA from a 120 kW feed

The supply covers only the active losses of a resonant circuit, so the power needed is 1/Q of the test capacity - three-phase 380 V, 50 Hz is enough.

 

Four units, one circuit

Supply, excitation transformer, reactors and divider are specified against the same duty and delivered with one terminal schedule for the whole set.

 

Current falls at breakdown

When the specimen fails the circuit detunes and loop current drops to 1/Q; the fault point is not burned away by a follow-through current.

 

 

20–300 Hz tuning

Frequency instability of 0.05% or less, voltage resolution 0.01 kV, and a sweep that can start and stop wherever you set it, up or down.

 

Three-stage withstand program

Each stage carries its own voltage and time. Cable work usually needs one stage; the other two are there when a specimen needs them.

 

Records by test time

Data stored under the testing time as the record number, printable from the controller and exportable over USB for the test file.

 

 

 

Specifications

 

   

System

Rated capacity 2400 kVA
Rated voltage 300 kV / 600 kV
Rated current 8 A / 4 A
Input power supply Three-phase 380 V, 50 Hz
Working frequency 20–300 Hz
Output distortion ≤1%
Duration 60 min at rated load, 60 min rest
Temperature rise ≤65 K at rated load
Quality factor Q ≥30 at 45 Hz
Measurement accuracy System RMS 1.5
Protection Over-current, over-voltage, flashover

Variable frequency supply - CHXB-120kW

Rated output capacity 120 kW
Working power 415 V, 50 Hz
Output voltage 0–400 V, single phase
Frequency range 20–300 Hz
Rated output current 300 A
Output waveform Sine wave
Voltage resolution 0.01 kV
Frequency instability ≤0.05%
Voltage instability ≤1.0%
Nonlinear distortion ≤1%
Running time 60 min at rated capacity
Noise level Less than 50 dB

Excitation transformer and reactors

Excitation capacity 120 kVA
Excitation input 400 V, single phase
Excitation outputs 5 kV / 10 kV / 20 kV
Excitation structure Oil type, 60 min at rated current
Reactor capacity each 1200 kVA
Reactor voltage / current 300 kV / 4 A
Reactor inductance 300 H per unit
Reactor Q value More than 50 at 45 Hz
Reactor structure Oil type, 60 min at rated current

Divider, environment and safety

Divider voltage 600 kV
HV capacitance 1000 pF
Dielectric loss tgσ less than 0.15%
Measuring accuracy 1.5
Ratio, console 2608034-1 26282:1 (1 section) / 13141:1 (2 sections)
Ratio, console 2608034-2 26428:1 (1 section) / 13214:1 (2 sections)
Ambient temperature −15 to 45 °C
Relative humidity ≤90% RH
Altitude ≤2500 m
Grounding resistance Below 2 Ω
 
   

Components 

HMCXZ-2400kVA/600kV Variable Frequency Resonant Test Set

 

Variable frequency power supply

CHXB-120kW/0.38kV · with console

  • 0–400 V single phase, 20–300 Hz, 300 A
  • Voltage resolution 0.01 kV, distortion ≤1%
  • Panel: Print Power, E-Stop, Reset, Power Indicator

01

Excitation transformer

120 kVA / 5 kV / 10 kV / 20 kV / 0.4 kV

  • 400 V single-phase input from the supply cabinet
  • 5 kV, 10 kV, 20 kV outputs chosen per test
  • Oil type; HV tail must be grounded

02

High voltage reactors

DK-1200kVA/300kV · 2 pcs

  • 1200 kVA, 300 kV, 4 A, 300 H each
  • Q above 50 at 45 Hz, oil immersed
  • Input on the base, output on the top

03

Capacitor voltage divider

FCR-600kV/1000pF

  • 1000 pF, dielectric loss below 0.15%
  • Accuracy 1.5, ratio by console serial number
  • Two grounding terminals, both to be earthed

04

Console and control

7-inch true-colour touch screen

  • 32-bit RISC CPU with a 7-inch touch screen showing resonance, boost and timing curves
  • Live true-RMS feedback of HV current, HV voltage and LV current
  • Calculates the resonant frequency from reactor inductance and specimen capacitance

05

 

 

Four functions

 

 

Set

Start and termination frequency, tuned voltage, manual withstand time, inductance, capacitance, three stages of voltage and time, alarm voltage, alarm current, flashover factor.

01

Man

Start, Tune, voltage step up and down, Timing, Stop. Close only after the voltage has returned to zero.

02

Auto

The sequence runs from the parameters without operator action; the operator monitors the equipment.

03

File

Query stored data by testing time, print from the controller after Print Power, or export to USB inserted before the test.

04

Notices

 

  • Two or more qualified high-voltage test operators; read the manual and complete repeated operation training first
  • Grounding resistance below 2 Ω - a higher value may damage the series resonance test system
  • Do not stand the reactors on metal or metal-mesh prefabricated ground: resonance may not be found and eddy currents can burn the coil
  • Connect and disconnect correctly; do not pull test leads at will from a live terminal, and check every connecting wire before power-up
  • Ground the housing pole as well as the supply cord earth; both divider grounding terminals must be earthed
  • Cut off the control supply of the variable frequency power source after every test, before the next one or at the end of the shift
  • Do not operate with covers removed, in a humid environment or in an explosive environment; keep the surface clean and dry
  • Use only the power cord supplied for this product, and observe the rating of every terminal.

 

 

FAQ

Q: Can one set do both 300 kV and 600 kV testing?

A:Yes. The two reactors are arranged in parallel for 300 kV at 8 A, or in series for 600 kV at 4 A. Rated capacity stays at 2400 kVA, and the excitation transformer offers 5 kV, 10 kV and 20 kV outputs to suit the arrangement.

Q: What is the delivery and duty position?

A: Each unit is rated for continuous operation for 60 minutes at rated load, followed by 60 minutes of rest, with a temperature rise of no more than 65 K. The supply unit runs continuously for 60 minutes at rated capacity, with component temperature within 65 K and noise below 50 dB.

Q: Where can the reactors be sited?

A:Each unit is rated for continuous operation for 60 minutes at rated load, followed by 60 minutes of rest, with a temperature rise of no more than 65 K. The supply unit runs continuously for 60 minutes at rated capacity, with component temperature within 65 K and noise below 50 dB.