Loop Resistance Meter

Loop Resistance Meter

The HM6090-200A is a fully automatic handheld contact resistance tester developed using high-frequency switching power supply technology and digital circuitry. Compliant with the power industry ........
Send Inquiry
Description
Technical Parameters

Wuhan Goldhome Hipot Electrical Co., Ltd. is one of the leading manufacturers and suppliers of loop resistance meter in China. With abundant experience, our factory offer high quality customized products made in China with competitive price. Welcome to contact us for quotation.

 

Products Video

 

HM6090 200A Handheld Contact Resistance Tester Display Video

                                                                       

 

Product Overview & Application Scenarios

2

Product Overview

The HM6090-200A is a fully automatic handheld contact resistance tester developed using high-frequency switching power supply technology and digital circuitry. Compliant with the power industry standard DL/T845.4-2004, it outputs a 100A DC current to precisely measure the contact resistance of conductive components with a resolution of 0.1μΩ. It is suitable for rapid reliability testing of electrical connections.

 

 

Application Scenarios

Power System Maintenance: Measure contact resistance of main contacts in high/low-voltage switchgear, circuit breakers, and isolating switches.

Industrial Equipment Inspection: Test resistance values at relay contacts, wire solder joints, and busbar connections.

Field Operations: Conduct portable testing at substations, distribution rooms, and other environments without fixed power sources.

1

Technical Specifications

 

Parameter

Specification

Model

HM6090S - 100A

Output Current

200A, 150A, 100A, 50A

Measurement Range

200A 0 - 1000uΩ

150A 0 - 1400uΩ

100A 0 - 2000uΩ

50A 0 - 10 mΩ

Resolution

0.1μΩ

Accuracy

± (reading x 0.5%+ 1 uΩ)

Test Time

fast, 10 ~ 60 seconds optional

Automatic shutdown

automatic shutdown after 5 minutes without operation

Power supply

built-in lithium battery or external charger, charger input 100 - 240VAC, 50Hz/60Hz

Charging voltage 12.6V
Charging current ≤3A
Host size 220mm ×168mm ×65mm
Host weight 1.6kg (excluding test line)

 

 

Panel introduction

HM6090 200A

LCD screen: 4.3 inch industrial high brightness color LCD screen, display operation menu and display measurement results.

Keyboard: used for the operation and parameter setting of various functions.

 

HM6090 200A 2

I+, I- : current output terminal.

V+, V- : voltage input jack.

HM6090 200A 3

USB port: Connects to an external USB disk for storing test data.

USB square port: Connects to an external printer.

Charging interface: use special charger for charging.

 

operation instructions

 

   After all test wires are connected, power on the instrument and enter the "main menu" interface after initialization, as shown in the picture below.

HM6090 200C

    Select "Start test" and press "Ok" to enter the "Prepare test" interface, as shown below.

HM6090 2001

 

   Current: Set the output power of this experiment to 50A/100A/150A/200A.

  If the circuit resistance exceeds the range of the corresponding tap during the test, the current may not reach the set current.

  Time: Set the test time of this experiment, 50A / 100A can choose "fast" or "10 / 20 / 30 / 40 / 50 / 60 seconds", 150A / 200A can choose "fast" or "5 seconds" test can press "Cancel" to stop the test at any time.

  Number: Set the sample number of this experiment

  Main display area: display the resistance value of the measured object.

  Vice display area: display the voltage value, current value and test time of the tested product.

 "Test Results" is shown below. Press left and right to move the cursor, and press OK to perform the selected operation.

HM6090 2002

 

   In the testing process, if the instrument has detected the fault of poor contact with the test line, the fault prompt box will pop up to alarm and stop the measurement.

   If the instrument detects that the internal temperature is too high, the fan will be automatically turned on for cooling, and the fan will be automatically turned off after the temperature drops.

  Continue measurement: Continue the resistance measurement with the current setting.

   Print data: Print the current test results by connecting to an external printer.

  Save data: Save the current test results to the local machine.

 On the Main menu interface, select "Save Query" and press "Ok" to enter the "Save Records" interface, as shown in the following figure.

HM6090 2003

   Usb flash drive storage: The local storage content is saved to an external USB flash drive.

 

Products Description

 

101

 

102

103

104

107

03

04

05

08

09

 

Hot Tags: loop resistance meter, China loop resistance meter manufacturers, factory