Products Video
HM501 Automatic Closed Cup Flash Point Tester Operation Video
Product Overview & Application Scenarios

HMKD Fully Automatic Open Cup Flash Point Tester, used to determine the open cup flash point and ignition point of petroleum products. The instrument employs an electric ignition method, requiring no flammable gases, and fully complies with the method requirements of ASTM D92 (GB 3536-2008) and GB 267-88. It incorporates an ARM series high-performance microprocessor, electrically erasable programmable read-only memory (capable of storing thousands of data records), a color LCD display and touchscreen, PID self-tuning, and other cutting-edge technologies. The open cup flash point tester's functions and performance meet the highest international standards, making it a specialized instrument for the petroleum, power, chemical, and commodity inspection industries to replace imported products.
Alternative Names: Open Cup Flash Point Tester, Fully Automatic Open Cup Flash Point Tester, Automatic Open Cup Flash Point Tester, Fully Automatic Open Cup Flash Point Tester, Automatic Open Cup Flash Point Tester, Open Cup Flash Point Tester
Technical Specifications
|
1 |
Measurement Range | Room Temperature to 400°C |
|
2 |
Test Type | Open Cup Flash Point or Ignition Point |
|
3 |
Temperature Sensor | Platinum Resistance Thermometer |
|
4 |
Precision |
±1°C |
|
5 |
Repeatability | Complies with GB3536-2008 (ASTM D92) and GB/T 267-88 |
|
6 |
Display | Color LCD display |
|
7 |
Data Storage | Stores up to 1,000 test results |
|
8 |
Ignition way |
Electronic ignition |
|
9 |
Cooling Method | Forced air cooling |
| 10 | Printer | Dot-matrix thermal printer |
| 11 | Self-Test Functions | Lifting rod, sweeping rod, printing, etc. |
| 12 | Power Consumption | ≤600 VA |
| 13 | Weight | Approx. 17 kg |
Key Features & Advantages

- Highly functional. This single unit can simultaneously measure both flash point and fire point, and print test results. It features a built-in clock chip that automatically displays the current date and time and retains data in the event of a power failure.
- High precision. Temperature error is controlled within ±1.5°C, with a resolution of 0.1°C.
- Excellent repeatability. When the testing environment complies with GB 3536 (ASTM D92) or GB/T 267-88, consecutive tests on the same sample yield flash point values differing by ≤4°C.
- High degree of automation. The instrument can automatically complete the testing process, perform automatic cooling, and provide automatic status notifications.
Hot Tags: cleveland open cup flash point tester, China cleveland open cup flash point tester manufacturers, factory