Series Transformer Comprehensive Characteristic Test Bench

Series Transformer Comprehensive Characteristic Test Bench

The HM5050 Series Transformer Comprehensive Characteristics Test Bench is a multifunctional, high - precision integrated testing device designed for transformer performance detection and experimentation.
Send Inquiry
Description
Technical Parameters

 Products Video

 

HM5050 Transformer Test Bench Display Video

 

 

 

Product Overview & Application Scenarios

logo7

The HM5050 Series Transformer Comprehensive Characteristic Test Bench is a multifunctional, high-precision integrated testing apparatus specifically designed for transformer performance testing and experimentation. This equipment combines multiple testing functions including no-load losses, load losses, turns ratio and connection group, DC resistance, and power frequency withstand voltage. It supports automatic data conversion and storage, making it suitable for transformer manufacturing, maintenance, and power system operation applications.

 

Technical Parameters

 

product-297-119

1. HMBTC-VI Power Analyser Technical Specifications
1) Basic measurement accuracy:
Voltage, current: ±0.1%
Power: ±0.2% (cosφ > 0.1), ±1.0% (0.01 < cosφ ≤ 0.1)
2) Voltage measurement range: AC 0–1000V
3) Current measurement range: AC 0–5A

 

product-237-303

2. HMGY-300kVA Three-Phase Electromagnetic Voltage Regulator Technical Specifications
1) Capacity range: 300kVA
2) Input voltage: 380V
3) Output voltage: 0–650V (other voltages available upon special request)
4) Frequency: 50/60Hz
5) Efficiency: 96%
6) Dielectric strength: 2000V / 60S < 10mA
7) Insulation resistance: >20MΩ
8) Ambient temperature: -25℃ to +40℃
9) Relative humidity: <95%
10) Temperature rise: <55℃
Noise level: <85dB

 

 

product-406-167

3.Technical Specifications for HMZP-160kVA Medium-Frequency Generator Set

1) Rated Capacity: 160kVA

2) Input Voltage: 415V

3) Output Voltage: 0–1kV

4) Frequency: 200Hz

 

 

product-333-332

4. Technical Specifications for 500kVA/0.8kV/1.6kV/2.4kV/6.4kV/24kV Intermediate Transformer

1) Rated Capacity: 500kVA

2) Operating Frequency: 50/150Hz

3) Output Voltage: 1.6kV, 2.4kV, 6.4kV, 24kV (4-tap output)

4) Output Current: 12–360A

5) Altitude: Not exceeding 1000m.

6) Ambient Temperature:

Maximum ambient temperature +40°C, maximum monthly average temperature +30°C

Minimum ambient temperature -25°C (for outdoor transformers), maximum annual average temperature +30°C

Minimum ambient temperature -5°C (for indoor transformers)

 

 

 

Hot Tags: series transformer comprehensive characteristic test bench, China series transformer comprehensive characteristic test bench manufacturers, factory, electrical test competitiveness testing, electrical test marketability testing, electrical test profitability testing