Transformer Capacity Loss Tester

Transformer Capacity Loss Tester

The HM5003 transformer capacity tester is a professional field testing device that can quickly and accurately measure the rated capacity of a transformer without applying a large current. This product features a wide-screen color LCD display.......
Send Inquiry
Description
Technical Parameters

Wuhan Goldhome Hipot Electrical Co., Ltd. is one of the leading manufacturers and suppliers of transformer capacity loss tester in China. With abundant experience, our factory offer high quality customized products made in China with competitive price. Welcome to contact us for quotation.

 

Products video

 

 

HM5003 Transformer Capacity Loss Tester Setting Introduction Video

Product Overview & Application Scenarios

 

111

The HM5003 transformer capacity tester is a professional field testing device that can quickly and accurately measure the rated capacity of a transformer without applying a large current. This product features a wide-screen color LCD display in English, with simple and quick menu operation and a user-friendly interface. The instrument has a built-in rechargeable battery, allowing it to operate without an external power supply. A full charge allows for continuous measurement of over 100 transformers. This is a multi-functional measuring instrument, equivalent to the functions of two ordinary instruments: a transformer capacity tester and a transformer parameter tester. It can be used to test transformer capacity, type, no-load current, no-load loss, load loss, impedance voltage, and other parameters.

 

Products Parameter

 

333

1.The output range of built-in battery

Voltage:0~10V

Current:0~10A

2. The input range of characteristic test power source

Voltage:0~750V

Current:0~100A

3. Accurate of test

Voltage, current:±0.2%

Power:±0.5%(CosΦ>0.1), ±1.0%(0.02

4. Working temperature: -20℃~+60℃

5. The requirement of charger

Electric supply: AC160V~265V

Adapter output: 12.6V 1000mA

6. Insulation

⑴ Insulation resistance between capacity , voltage, current to enclosure ≥100MΩ

⑵ bear the 2kV power frequency (effective value) between the

input power and machine enclosure, testing time is 1 minute.

7. Volume: 32cm×25cm×12cm

8. Weight: 2.5KGS

 

Interface  Overview

 

1.Operating Panel Diagram  
The operating panel of this instrument is shown in Figure 1: It includes a printer, LCD screen, keyboard, capacity test connection ports, characteristic test terminals, and data upload communication interfaces.

HM5003

Figure 1

 

2. Main Menu
    After turning on the power switch, the device automatically enters the main menu interface (Figure 2).
   The main menu primarily includes five functions: "Capacity Test," "No-Load Loss," "Load Loss," "Management Query," and "System Settings." Users can select the desired function using the "↑" and "↓" keys, then press the "Confirm" key to enter. Simultaneously, the instrument accurately displays the current system time based on its internal clock chip.

HM500

 Figure 2

 

3.Wiring Method

  Wiring Method for Measuring Short-Circuit Losses of Single-Phase Transformers Using a Single-Phase Power Supply

  The wiring configuration is essentially identical to that used for measuring no-load losses of single-phase transformers with a single-phase power supply. Refer to Figures 3, 4, and 5. The only difference is that during short-circuit loss testing, the high-voltage side is typically designated as the test terminal, while the low-voltage side serves as the non-test terminal. Additionally, the non-test terminal requires manual short-circuiting.

HM5003

Figure 3 Schematic Diagram of Direct Connection Method for Single-Phase No-Load Testing 

HM50031

Figure 4 Wiring Diagram for External PT and CT Connection in Single-Phase No-Load Testing

HM50032png

Figure 5 Wiring Diagram for External CT Connection in Single-Phase No-Load Testing

Software Installation and Removal

 

Installing Drivers on Windows XP:

  First, install the drivers. Connect the data cable supplied with the tester to the computer's USB port. The system prompt appears as shown in Figure 1.
 

Figure 1 Beginning Driver Installation

product-517-377

   Select "Install from a list or specific location (Advanced) (S)" and click "Next." The screen shown in Figure 2 appears. 
 

Figure 2: Selecting the Driver Search Method

2


   Click "Browse" and navigate to the "CP210x_Drivers" directory on the CD provided with the instrument, as shown in Figure 3.


Figure 3: Selecting the Driver Directory

3


  Then click "Next," displaying Figure 4. Repeat this process once more to complete the driver installation.
 

Figure 4: Driver Installation Complete

4

 