Wuhan Goldhome Hipot Electrical Co., Ltd. is one of the leading manufacturers and suppliers of hm-ydjw-300kva/300kv pd-free power frequency ac hipot tester in China. With abundant experience, our factory offer high quality customized products made in China with competitive price. Welcome to contact us for quotation.
Products video
Products Description

The HM-YDJW-300kVA/300kV PD-free Power Frequency AC Hipot Tester is designed for high-voltage AC insulation withstand testing and partial discharge measurement.
The equipment is suitable for factory testing of electrical equipment with voltage levels below 300kV. According to the operation manual, its applications include transformer insulation withstand voltage testing and partial discharge measurement.
The complete test system consists of an operation desk, an integrated power supply cabinet, a 300kVA/300kV test transformer, a current-limiting resistor, and a capacitive voltage divider.
The integrated power supply cabinet combines the power isolation transformer, voltage regulator, isolation step-up filter, and power compensation components. This configuration provides the power supply and voltage adjustment functions required for the test transformer.
The system operates at power frequency of 50Hz and provides an AC output voltage adjustable from 0 to 300kV through the test transformer.
Products Features
-
1. 300kVA Test Capacity
The HM-YDJW test transformer has a rated capacity of 300kVA and a rated output voltage of AC 0–300kV.
It is designed for high-voltage AC insulation withstand testing in factory environments.
2. Integrated Power Supply Cabinet
The power supply cabinet integrates several functional units:
Power isolation transformer
Voltage regulator
Isolation step-up filter
Power compensation unit
The integrated arrangement provides the low-voltage power supply and adjustment functions for the high-voltage test transformer.
3. Power Frequency AC Testing
The system operates at 50Hz. The test transformer is single-phase and uses an insulated tank enclosure.
The equipment is intended for power-frequency AC withstand voltage testing rather than variable-frequency resonant testing.
4. Automatic and Manual Operation
The operation desk supports automatic and manual test modes.
In automatic mode, operators can configure three test stages, including the target voltage, voltage boost speed, and withstand time for each stage.
Manual mode provides voltage boost and step-down operations through the control interface.
5. System Partial Discharge Requirement
The operation manual specifies that, under a shielded test environment and with the harmonic component of the test power supply below 5%, the partial discharge level of the complete system should be less than 10pC at rated voltage.
This requirement describes the system-level partial discharge condition specified in the manual.

Products Parameters
Complete Test Transformer
| Parameter | Specification |
|---|---|
| Model | HM-YDJW-300kVA/300kV |
| Structure | Insulated tank enclosure |
| Number of phases | Single-phase |
| Rated frequency | 50Hz |
| Rated capacity | 300kVA |
| Input voltage | 1kV |
| Output voltage | AC 0–300kV |
| Output current | 1.0 (unit not specified in manual) |
Integrated Power Supply Cabinet
| Component | Parameter | Specification |
|---|---|---|
| Power isolation transformer | Rated capacity | 100kVA |
| Power isolation transformer | Input voltage | 400V |
| Power isolation transformer | Output voltage | 400V |
| Voltage regulator | Rated capacity | 100kVA |
| Voltage regulator | Input voltage | 380V |
| Voltage regulator | Output voltage | 0–400V |
| Voltage regulator | Output current | 250A |
| Isolation step-up filter | Rated capacity | 100kVA |
| Isolation step-up filter | Input voltage | 0–400V |
| Isolation step-up filter | Output voltage | 0–1kV |
| Power compensation | Rated capacity | 250kVA |
| Power compensation | Rated voltage | 400V |
All power supply cabinet components operate at 50Hz.
Current-Limiting Resistor
| Parameter | Specification |
|---|---|
| Model | HMRV-300kV/1-4 |
| Rated frequency | 50Hz |
| Rated voltage | 300kV |
| Rated current | 1A |
Capacitive Voltage Divider
| Parameter | Specification |
|---|---|
| Model | HMFRC-300kV/0.001uF |
| Rated frequency | 50Hz |
| Nominal capacitance | 1000pF |
| Rated voltage | 300kV |
| Dielectric loss | Less than 0.5% |
| Voltage ratio | 687:1 |
| Measuring accuracy | 1.5 class |
Products display



Hot Tags: hm-ydjw-300kva/300kv pd-free power frequency ac hipot tester, China hm-ydjw-300kva/300kv pd-free power frequency ac hipot tester manufacturers, factory