20kVA/100kV Oil-Immersed AC Test Transformer for Insulation Testing

20kVA/100kV Oil-Immersed AC Test Transformer for Insulation Testing

The Goldhome HMYDJW-20kVA/100kV AC withstand voltage test system combines an oil-immersed test transformer with an automatic control console. Its control functions are designed to support test parameter setting, voltage adjustment, timing, status monitoring, and test data management.
Send Inquiry
Description
Technical Parameters

Wuhan Goldhome Hipot Electrical Co., Ltd. is one of the leading manufacturers and suppliers of 20kVA/100kV Oil-Immersed AC Test Transformer for Insulation Testing in China. With abundant experience, our factory offer high quality customized products made in China with competitive price. Welcome to contact us for quotation.

 

 

Products video

                    

 

Product Overview

 

20 kVA / 100 kV AC Withstand Voltage Test Set
 

The Goldhome HMYDJW-20kVA/100kV AC withstand voltage test system combines an oil-immersed test transformer with an automatic control console. Its control functions are designed to support test parameter setting, voltage adjustment, timing, status monitoring, and test data management.

The operating manual describes a 27-inch LCD screen and a Chinese-language touch interface. Operators can select automatic or manual test modes, configure test parameters, monitor voltage and current readings, and review test records.

In automatic mode, the system can raise the voltage to the configured target, begin timing when the target is reached, and reduce the voltage automatically when the configured test time ends. The manual also describes a stop function that returns the voltage regulator to its starting position.

The system's actual performance and control functions should be confirmed against the supplied configuration and operating manual.

logo6

01

20 kVA

Rated capacity

02

100 kV

Max test voltage

03

0.2A

Max output current

04

27"

Touch screen console

 

Control System Features

 

 

27-Inch LCD Touchscreen

The console displays voltage, current, time, operating status, and prompts. The touch interface provides access to parameter settings, automatic testing, manual testing, and data viewing.

Automatic Test Sequence

The automatic test interface supports configured test stages. The manual describes settings for the first, second, and third stages, including target voltage, test duration, and voltage rise speed.

Manual Voltage Adjustment

In manual mode, operators can use the touchscreen controls to raise or lower the voltage. A return-to-zero function is also described.

Automatic Timing

When the configured target voltage is reached in automatic mode, the system starts the test timer. After the configured time expires, the system reduces the voltage and returns to zero.

Alarm and Protection Functions

The manual describes audible alarms for contactor closing and abnormal voltage-signal acquisition. It also identifies overvoltage, low-voltage current, and high-voltage current protection functions within the control system.

Test Record Export

The data interface allows operators to query test records by date range and save the displayed data to an Excel file.

 

Technical Specifications

 

Parameter Specification  
Product model HMYDJW-20kVA/100kV  
Rated capacity 20kVA  
High-voltage range 0–100kV  
High-voltage current range 0–0.2A  
Low-voltage range 0–380V  
Low-voltage current range 0–52.6A  
Supply voltage AC 380V ±10%  
Supply frequency 50Hz ±2Hz  
Display 27-inch LCD  
Interface Chinese-language touch interface  
Test modes Automatic and manual  
Manual voltage rise speed Adjustable from 50 to 3000V/s  
Manual voltage reduction speed Adjustable from 50 to 5000V/s  
Automatic stage voltage settings 0–100kV  
Configurable stage test time 0–9999s  
Test data Query by date range and export to Excel  

 

FAQ

 

Q: Does the console support both automatic and manual testing?

A: Yes. The manual describes both operating modes.

Q: Can I configure different test stages?

A: The parameter-setting interface describes up to three automatic test stages, each with configurable voltage and duration settings.

Q: What data can operators monitor?

A: The automatic test interface displays high voltage, target voltage, leakage current, low-voltage current and voltage, withstand timing, and operating status.

Hot Tags: 20kVA/100kV Oil-Immersed AC Test Transformer for Insulation Testing, China 20kVA/100kV Oil-Immersed AC Test Transformer for Insulation Testing manufacturers, factory